![]() Three forms of detection: burglary, fire and emergency (see your installer for which forms of detection are installed).K5320V2 4/04 Rev.For VISTA-20P / VISTA-20PSIA & VISTA-15P / VISTA-15PSIAįull User Guide Available Online: This Quick Guide describes the most frequently used features and functions of your system.Ĭongratulations on your ownership of a Honeywell Security System. REFER TO INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED FOR WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM.Ĭopyright © 2004 Honeywell International Inc. Voltage: 12VDC Current: 55mA…sounder on, 30mA…standby, alarm sounder off. Sounder: Piezo-electric (fire alarm is loud, pulsing single tone burglary alarm is loud, continuous, dual tone). Physical: 4-1/4"H x 5-5/8"W x 1"D Display: Fixed-Word LCD. Press any key to exit, or wait 10 seconds to automatically exit viewing mode. Press and hold down the and keys at the same time for about 3 seconds. Pwr Data Out Wire Color Green Black Red Yellow Keypad ÎG – + ÏY Wiring Table Control Panel Data In – Aux Pwr (GND) + Aux. Wire directly from the keypad’s terminal block to the terminal block on the control board. Mount the case back to a wall or electrical box. Route wiring from the control panel through the opening in the case back. Remove the case back by pushing down two "snaps." See diagram that follows. The keypads can be surface mounted directly to a wall, or to a single- or double-gang electrical box. Exit address mode: Press to save the displayed address and exit address mode. Note that address "31" sets the keypad to nonaddressable mode. Enter the proper "ones" digit of the keypad's address. The cursor moves to the "ones" digit position. Enter the keypad's address: Enter the proper "tens" digit of the keypad's address. The cursor moves back to the "tens" digit position. Set the current address to "00": Press to clear the current "tens" digit. NOTE: The keypad will not enter address mode if the panel to which it is connected is in programming mode. You must power down, power up and start address mode again. If 10 seconds have passed with no key entry, the keypad automatically exits address mode. (If unable to enter address mode, power up and try again.) The current keypad address is displayed, and the cursor is under the "tens" digit. Within 60 seconds of power-up, press and hold down the and keys at the same time for 3 seconds. To change the keypad's address, do the following: 1. Refer to the Installation and Setup Guide of the control panel being used for correct address settings and other details. The keypad can be set either for an address of 00-30, or to the non-addressable mode (31). The following key pairs are used by the ADEMCO 6148 to manually activate silent emergency, audible emergency, personal emergency, or fire alarms: See the control's instructions for details. These key pairs may be used to activate panic alarms. The keypad also features special-function key pairs. NOTE: TO REMOVE CASE BACK PUSH IN THE TWO MOUNTING SNAPS LOCATED ALONG THE BOTTOM OF THE KEYPAD AND LIFT UP. Lights when the system is "ready" to be armed. Red (ARMED) Green (READY) Lights when the system is armed in any mode. The following table describes the LEDs and their functions: The ADEMCO 6148 keypad has a fixed-word display and a 2digit zone identifier. The keys on the keypads are continuously backlit for convenience. The ADEMCO 6148 is an addressable remote keypad designed for use with ADEMCO control panels.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |